Technical Data
SMA Solar Technology AG
68
SB25-30-IA-en-51
Installation Manual
*
EN 50438: does not apply to all country standard deviations of EN 50438.
DK 5940: only applies for
SB 3000-IT.
Climatic Conditions in Accordance with IEC 60721-3-4, Installation Type C,
Category 4K4H
Climatic Conditions in Accordance with IEC 60721-3-4, Transport Type E,
Category 2K3
Features
Country standards, as of 11/2011*
VDE0126-1-1
AS4777
C10/11
PPDS
GBT19939-2005
PPC
EN 50438
RD1663
RD661
G83/1-1
DK5940
VDE-AR-N 4105
UTE C 15-712-1
Extended temperature range
− 25°C … +60°C
Extended humidity range
0% … 100%
Extended air pressure range
79.5 kPa … 106 kPa
Temperature range
− 25°C … +70°C
DC connection
SUNCLIX DC connector
AC connection
AC connector
Display
LC text display
Bluetooth
Optional
RS485, galvanically isolated
Optional