background image

SMA Solar Technology AG

Opening and Closing

Installation Manual

SB25-30-IA-en-51

45

5. Unlock and disconnect all DC connectors. To do

this, insert the screwdriver into one of the side slits
(blade width: 3.5 mm) and pull the DC connectors
straight down. Do NOT pull ON THE CABLE while
doing this.

☑ All DC connectors are disconnected from the

inverter. The inverter is completely disconnected
from the PV array.

6. Pull out the AC plug.

7. Check whether all LEDs and the display have gone out.

DANGER!
Danger to life due to high voltages in the inverter

The capacitors in the inverter require 15 minutes to discharge.

• Wait 15 minutes before opening the inverter.

This manual is related to the following products: