SMA SB 2500 Installation User Manual
Page 30

Electrical Connection
SMA Solar Technology AG
30
SB25-30-IA-en-51
Installation Manual
3. Ensure the cable is correctly in place.
4. Push the cable gland toward the thread and fasten to a torque of 2 Nm.
☑ The DC connectors are assembled and can now be connected to the inverter as described in
Section 5.4.4 "Connecting the PV Array (DC)" (page 32).
Result
Measure
☑ If the conductors are visible in the hollow
cavity of the clamping bracket, the cable is
in the correct position.
• Proceed to step 4.
☑ If the conductors are not visible in the
hollow cavity, the cable is not in the correct
position.
• Loosen the clamping bracket. For this
purpose, use a screwdriver with a blade
width of 3.5 mm.
• Remove the cable and start again from
step 1.
This manual is related to the following products: