beautypg.com

SMA SB 2500 Installation User Manual

Page 67

background image

SMA Solar Technology AG

Technical Data

Installation Manual

SB25-30-IA-en-51

67

Protective Devices

General Data

Overvoltage category according to IEC 60664-1

III

Maximum cable length at conductor cross-section
of 2.5 mm²

12.5 m

DC reverse polarity protection

Short-circuit diode

Input-side disconnection device

Electronic Solar Switch

DC overvoltage protection

Thermally monitored varistors

AC short-circuit current capability

Current control

Mains monitoring

SMA Grid Guard 2.1

Maximum permissible fuse protection

16.0 A

Earth fault monitoring

Insulation monitoring: R

iso

> 1 M Ω

Galvanic isolation

Available

Width x height x depth with Electronic Solar Switch

440 mm x 339 mm x 214 mm

Weight

32 kg

Length x width x height of packaging

532 mm x 392 mm x 318 mm

Transport weight

36.6 kg

Climatic category according to IEC 60721-2-1

4K4H

Operating temperature range

− 25°C … +60°C

Maximum permissible value for relative humidity,
non-condensing

100%

Maximum operating altitude above MSL

2 000 m

Noise emission (typical)

≤ 30 dB(A)

Power loss in night operation

≤ 0.25 W

Topology

LF transformer

Cooling concept

Convection

Electronics degree of protection according to
IEC 60529

IP65

This manual is related to the following products: