Technical Data
SMA Solar Technology AG
66
SB25-30-IA-en-51
Installation Manual
11.2 Sunny Boy 3000
DC Input
* The maximum open-circuit voltage which can occur at a cell temperature of − 10°C, must not exceed the maximum input voltage.
AC Output
Maximum DC power at cos φ = 1
3 200 W
Maximum input voltage*
600 V
MPP voltage range
268 V … 480 V
Rated input voltage
350 V
Minimum input voltage
268 V
Start input voltage
330 V
Maximum input current
12 A
Maximum input current per string
12 A
Number of independent MPP inputs
1
Strings per MPP input with ESS
3
Strings per MPP input
1
Rated power at 230 V, 50 Hz
2 750 W
Maximum apparent AC power
3 000 VA
Rated mains voltage
230 V
Nominal AC voltage
220 V/230 V/240 V
AC voltage range
160 V … 265 V
Nominal AC current at 220 V
12.5 A
Nominal AC current at 230 V
12.0 A
Nominal AC current at 240 V
11.5 A
Maximum output current
15.0 A
Total harmonic factor of output current at
AC THF voltage < 2%,
AC power > 0.5 AC rated power
≤ 3%
Rated power frequency
50 Hz
AC power frequency
50 Hz/60 Hz
Operating range at AC power frequency 50 Hz
45.5 Hz … 54.5 Hz
Operating range at AC power frequency 60 Hz
55.5 Hz … 64.5 Hz
Power factor at rated power
1
Feed-in phases
1
Connection phases
1