SMA SB 2500 Installation User Manual
Page 48

Opening and Closing
SMA Solar Technology AG
48
SB25-30-IA-en-51
Installation Manual
7. If an Electronic Solar Switch is installed, check the
Electronic Solar Switch for wear, as described in
Section 8.2 "Checking the Electronic Solar Switch
for Wear" (page 49), and reattach it firmly.
8. Switch on the miniature circuit-breaker.
9. Check whether the display and the LEDs indicate a
normal operating state
(see Section 6 "Commissioning" (page 37)).
☑ The inverter is closed and in operation.
NOTICE!
Damage to the inverter due to moisture and dust intrusion
If the Electronic Solar Switch is not plugged in or incorrectly plugged in during operation,
moisture and dust can penetrate the inverter.
If the Electronic Solar Switch is not correctly plugged in, this can cause contacts to wear in
the Electronic Solar Switch or the Electronic Solar Switch might fall down. This can result in
yield loss and damage to the Electronic Solar Switch.
Always plug in the Electronic Solar Switch as described in the following:
• Do not tighten the screw in the Electronic Solar Switch.
• Firmly plug in the Electronic Solar Switch until it is flush with the enclosure.
• Ensure that the maximum distance between the Electronic Solar Switch and the
enclosure is 1 mm.