11.2 General Data
11.2.1 Protective Devices
* optional
Width x height x depth
450 mm x 350 mm x 236 mm
Width x height x depth with
Electronic Solar Switch
450 mm x 352 mm x 236 mm
Weight
38 kg
Length x width x height of packaging
580 mm x 470 mm x 390 mm
Transport weight
43.7 kg
Climatic category according to IEC 60721-2-1
4K4H
Operating temperature range
− 25°C ... +60°C
Maximum permissible value for relative humidity,
non-condensing
100%
Maximum operating altitude above MSL
2 000 m
Noise emission (typical)
≤ 40 dB(A)
Power loss in night operation
< 0.1 W
Topology
LF transformer
Cooling concept
OptiCool
Fan connection
designed for safe disconnection
in accordance with DIN EN 50178:1998-04
Electronics degree of protection according to
IEC 60529
IP65
Protection class according to IEC 62103
I
DC reverse-polarity protection
Short-circuit diode
Input-side disconnection device*
Electronic Solar Switch,
DC plug-in system SUNCLIX
DC overvoltage protection
Thermally monitored varistors
AC short-circuit current capability
Current control
Grid monitoring
SMA Grid Guard 2.1
Maximum permissible fuse protection
25 A
Ground fault monitoring
Insulation monitoring: R
iso
> 1 M Ω