beautypg.com

9 troubleshooting, 1 blink codes, Troubleshooting – SMA SB 3300 Installation User Manual

Page 52: Blink codes

background image

Troubleshooting

SMA Solar Technology AG

52

SB33_38-IEN111851

Installation Guide

9 Troubleshooting

If the inverter displays blink codes or error messages other than those described in the following
section, contact the SMA Serviceline.
You will also find a description of display messages during operation, status messages and measuring
channels in the user manual provided.
Do not perform any repairs that are not described here and take advantage of the 24-hour
replacement service (inverter ready for shipping and handed over to a haulage company within
24 hours) and the SMA Solar Technology AG repair service instead.

9.1 Blink Codes

Green

Red

Yellow

Status

is glowing continuously

is not glowing

is not glowing

OK
(feeding-in operation)

is glowing continuously is not glowing

Ground fault or varistor
defective

is glowing
continuously

OK
(initialization)

is flashing quickly
(3 x per second)

is not glowing

is not glowing

OK (stop)

is glowing continuously is not glowing

Ground fault or varistor
defective

is flashing slowly
(1 x per second)

is not glowing

is not glowing

OK (waiting, grid
monitoring)

goes out briefly
(approx. 1 x per second)

is not glowing

is not glowing

OK (derating)

is glowing continuously is not glowing

Ground fault or varistor
defective

is not glowing

is not glowing

is not glowing

OK
(overnight shutdown)

is not glowing

Error

is glowing continuously is not glowing

Ground fault or varistor
defective

glowing/flashing

Ground fault or varistor
defective and
disturbance

This manual is related to the following products: