5.5.2 Assembling the DC Plug Connector

In order to connect to the inverter, all connection cables of the PV modules must be equipped with the
DC plug connectors provided.
To assemble the DC plug connectors, proceed as follows: Ensure the plug connectors have the correct
polarity. The DC plug connectors are identified with "+" and " − ".

Cable Requirements

• Use a PV1-F cable.

Procedure

1. Insert stripped cable into the plug up to the limit.

2. Press the clamping bracket down until it audibly

snaps into place.

3. Ensure the cable is correctly in place.

Result

Measure

☑ If the conductors are visible in the hollow

cavity of the clamping bracket, the cable is
in the correct position.