2 input voltage range 96 v dc, 1 pv generator connection data, 2 grid connection data – SMA SB 700 User Manual
Page 36: Input voltage range 96 v dc, Pv generator connection data, Grid connection data
Technical data
SMA
Technologie AG
Page 36
SB700-11:SA2006
Installation Guide
7.2 Input voltage range 96 ... 200 V DC
7.2.1 PV generator connection data
7.2.2 Grid connection data
Max. input open circuit voltage
U
PV 0
250 V (based on -10 °C cell
temperature)
Input voltage, MPP range
U
PV
96 V ... 200 V
Max. input current
I
PV m ax
7 A
Max. input power
P
D C
670 W
Recommended generator power
750 Wp
All-pole isolator on the DC input side
DC plug connector
Overvoltage protection
Thermally monitored varistors
Voltage ripple
U
pp
< 10 % of the input voltage
Insulation protection
Ground fault monitoring
(Riso > 1 MΩ)
Operating consumption
< 4 W (standby)
Reverse polarity protection
Short circuit diode
Nominal output power
P
AC nom
600 W
Peak output power
P
AC m ax
600 W
Nominal output current
I
AC nom
2.6 A
Harmonic distortion of output current
(at K
U grid
< 2 %, P
AC
> 0.5 P
AC nom
)
K
IAC
< 3 %
Short-circuit strength
Grid-side via current regulation
Operating range, grid voltage
U
AC
198 ... 260 V AC
Operating range, grid frequency
f
AC
49.8 ... 50.2 Hz
All-pole isolation on grid side
Independent disconnection device
(MSD), redundant design
Phase shift angle (based on the
current's fundamental frequency)
cos phi 1
Overvoltage category
III
Test voltage (50 Hz)
1.3 kV (1 s routine testing / 5 s type
testing)
Test surge voltage
4 kV (serial interface: 6 kV)
Own consumption in night mode
0.1 W