7.2 Input voltage range 96 ... 200 V DC

7.2.1 PV generator connection data

7.2.2 Grid connection data

Max. input open circuit voltage

U

PV 0

250 V (based on -10 °C cell
temperature)

Input voltage, MPP range

U

PV

96 V ... 200 V

Max. input current

I

PV m ax

7 A

Max. input power

P

D C

670 W

Recommended generator power

750 Wp

All-pole isolator on the DC input side

DC plug connector

Overvoltage protection

Thermally monitored varistors

Voltage ripple

U

pp

< 10 % of the input voltage

Insulation protection

Ground fault monitoring
(Riso > 1 MΩ)

Operating consumption

< 4 W (standby)

Reverse polarity protection

Short circuit diode

Nominal output power

P

AC nom

600 W

Peak output power

P

AC m ax

600 W

Nominal output current

I

AC nom

2.6 A

Harmonic distortion of output current
(at K

U grid

< 2 %, P

AC

> 0.5 P

AC nom

)

K

IAC

< 3 %

Short-circuit strength

Grid-side via current regulation

Operating range, grid voltage

U

AC

198 ... 260 V AC

Operating range, grid frequency

f

AC

49.8 ... 50.2 Hz

All-pole isolation on grid side

Independent disconnection device
(MSD), redundant design

Phase shift angle (based on the
current's fundamental frequency)

cos phi 1

Overvoltage category

III

Test voltage (50 Hz)

1.3 kV (1 s routine testing / 5 s type
testing)

Test surge voltage

4 kV (serial interface: 6 kV)

Own consumption in night mode