beautypg.com

SMA SB 700 User Manual

Page 29

background image

SMA

Technologie AG

Installation

Installation Guide

SB700-11:SA2006

Page 29

To adjust the input voltage, follow these steps:

1.

Open the Sunny Boy 700 as described in section 6.1.

2.

Pull the terminal upwards out of the terminal block and plug it into the
appropriate slot.

3.

Plug the jumper provided in the accessories kit into the corresponding slot on the
controller board. If you want to use the Sunny Boy 700 with the maximum input
voltage range, then do not use the jumper.

4.

Once the jumper is in place and the terminal plugged into the correct slot, close
the Sunny Boy 700 as described in section 6.2.

There is a schematic view of the connectors in the table below.

Voltage range

Terminal block

Jumper

119 ... 250 V DC

(factory setting)

96 ... 200 V DC

73 ... 150 V DC

Terminal in

slot 1

150V

ENS2

200V

ENS1

No jumper used

Terminal in

slot 2

150V

ENS2

200V

ENS1

Jumper fitted to

"200 V" position

Terminal in

slot 3

150V

ENS2

200V

ENS1

Jumper fitted to

"150 V" position