beautypg.com

SMA SB 700 User Manual

Page 22

background image

Installation

SMA

Technologie AG

Page 22

SB700-11:SA2006

Installation Guide

Connecting the AC output with PG13.5

To connect a cable with a maximum diameter of 13.5 mm, proceed as follows.

1.

Press the sealing ring into the cord grip.

2.

Now slide the pressure screw over the cable first of all, followed by the cord
grip with the sealing ring in it. Now slide the threaded sleeve over the cable.

3.

Now connect the individual conductors to the socket element in sequence.

-

Protective earth PE (green/yellow) to the screw terminal
with the earth sign. It is required that the PE wire is
slightly longer than the L and N wires.

-

Neutral conductor N (blue) to screw terminal 1.

-

Live L (brown or black) to screw terminal 2.

-

Terminal 3 remains unused.

4.

Make sure the wires are securely connected.

Sealing ring

Cord grip

Cord grip with

sealing ring

Pressure screw

Threaded sleeve

1

2

3

Terminals in the socket

element

Cord grip with

sealing ring

Pressure screw

Threaded sleeve

Socket element

Connected wires