Connecting the AC output
A round plug connector system is used, which allows various cable diameters to be
used in the cable outlet. For this reason, the accessories kit includes a PG13.5
pressure screw and a PG16 pressure screw. Check which screw fitting is the right one
for your AC cable.
To connect up the AC output, follow these steps:
3.
Now take the AC connection socket parts included in delivery of your Sunny Boy
700 and connect up the cable, with shielding and insulation stripped, as
described on the following pages:
Before you connect the mains cable to the AC connection socket,
make sure that no voltage is present at the cable.
1.
Check the grid voltage. If this is higher than
260 V, the Sunny Boy 700 will not be fully
operational. In this case, contact the local grid
operator for assistance.
Max. 260 V!
The maximum grid voltage for feeding
electricity into the grid is 260 V!
2.
Isolate the grid connection (switch the line circuit
breaker to its "off" position), make sure it cannot
be switched back on, and test to make sure no
voltage is present.
You must make sure that no voltage is
present at the AC output before opening
the Sunny Boy.
1.
2.
3.
Off!
Sealing ring
for PG13.5
Cord grip
for PG13.5
Threaded sleeve
Socket element
Pressure screw
for PG13.5
Pressure screw
version PG16
for large cable cross-
sections