Maintenance and Care

SMA Solar Technology AG

64

Sensorbox-IEN100914

Installation Guide

3. Unscrew the old cable gland from the

Sunny SensorBox.

4. Place the appropriate gasket ring onto the thread

of the new cable gland.

5. Screw the cable gland into the Sunny SensorBox until finger tight (torque: 0.8 Nm).
6. Remove the porous rubber seal in the Sunny SensorBox lid and replace it with the new one.
7. Reinsert the relevant cable into the enclosure and make all the necessary connections.
8. Make sure the cable opening seals of the cable gland are seated properly.
9. Screw the lock nuts onto the cable gland until finger tight to fix the cable (torque: 0.8 Nm).

10. Close the Sunny SensorBox (see page 61).

☑ The gaskets of the cable gland have been replaced.

9.5 Care

Use a soft and moist cloth to clean the Sunny SensorBox and the RS485 Power Injector or SMA Power
Injector with Bluetooth. Make sure the cloth is made of scratch-free material so as to avoid damaging
the surface of the enclosure. If there is a considerable amount of dirt, you can also use a mild, non-
abrasive and non-corrosive cleaning agent.

NOTICE!
Damage to Sunny SensorBox from water seeping in.

Tightening the cable gland may cause the gasket ring to become damaged or loose its
proper threading position in the cable gland. The Sunny SensorBox will no longer be
watertight as a result.

• Make sure the gasket ring is seated properly.