2 configurable parameters, Configurable parameters – SMA Sensorbox User Manual
Page 72

Parameters
SMA Solar Technology AG
72
Sensorbox-IEN100914
Installation Guide
Anemometer
*
* If no anemometer is connected or the wind velocity exceeds the measurement range, "0" is displayed in these channels.
12.1.2 Configurable Parameters
Name
Description
WindVel m/s
wind velocity in m/s
WindVel km/h
wind velocity in km/h
WindVel mph
wind velocity in mph
Name
Description
Value / range
Explanation
Default
value
DevNam
device name
Text
allocation of a user-defined
device name
TmpUnit
unit of temperature
°C
degrees Celsius
°C
K
Kelvin
°F
degrees Fahrenheit
WindUnit unit for wind velocity
m/s
m/s
km/h
mph
DevRs
Sunny SensorBox
reset
0 ms … 255 ms for reset, enter "1" and save;
the specified parameter will
not be added and the LED in
the Sunny SensorBox remains
off for 60 seconds
0
RS485DI
response delay of the
Sunny SensorBox to
the RS485 bus;
this parameter is only
visible if you are
logged in as an
"installer" in the
communication device
0 ms … 1.000 ms if you are using a Sunny Boy
Control/Plus, this parameter
must be set to "200 ms"; if you
are using a Sunny WebBox,
the response delay can be
reduced to "10 ms".
200 ms