13 technical data, Technical data – SMA SIC 50 User Manual
Page 42

Technical Data
SMA Solar Technology AG
42
SIC50-IA-en-11
Installation Guide
13 Technical Data
SIC50-MPT
Input (PV array)
Max. PV power (12 V / 24 V / 48 V)
630 W / 1 250 W / 2 400 W
Max. DC voltage
140 V
DC
Optimal MPPT voltage range
(12 V / 24 V / 48 V)
25 V … 60 V / 40 V … 80 V / 70 V … 100 V
Number of MPP trackers
1
Max. PV current for 12 V / 24 V / 48 V system
40 A / 40 A / 40 A
PV current control unit
MPPT (approximate current control every minute,
fine control every two seconds)
Clamping position
screw terminals
Recommended cable cross-section
10 mm²
Max. cross-section of cables that can be
connected
16 mm²
Torque (bolt or screw terminals)
0.5 Nm ... 0.6 Nm
Output (battery)
Nominal DC power up to 40 °C
(12 V / 24 V / 48 V)
600 W / 1 200 W / 2 400 W
Power limitation at 50 °C / 60 °C
12 V : 600 W / 600 W
24 V : 1 200 W / 1 000 W
48 V : 1 500 W / 1 000 W
Nominal battery voltage (adjustable)
12 V / 24 V / 48 V
Battery voltage range
8 V … 65 V
Battery type
flooded and sealed lead acid batteries
Max. charging current (12 V / 24 V / 48 V)
50 A / 50 A / 50 A
Permanent charging current (12 V / 24 V / 48 V)
50 A / 50 A / 50 A
Charge control
IUoU
Clamping position
screw terminals
Recommended cable cross-section
10 mm²
Max. cross-section of cables that can be
connected
16 mm²
Fuse type (max. contact unit)
thermal fuse (2 x 30 A)
Torque
(bolt or screw terminals)
0.5 Nm ... 0.6 Nm