beautypg.com

SMA SIC 50 User Manual

Page 26

background image

Electrical Connection

SMA Solar Technology AG

26

SIC50-IA-en-11

Installation Guide

Configuring the Software

Use a terminal program in order to display the measured values on the PC. There are various terminal
programs available, e.g., Hyper Terminal. Hyper Terminal is a Microsoft Windows standard program
and is located under „Start\Programs\Accessories\Communication“.
The following table shows the connection settings for the terminal program:

Pin Assignment of the RJ45 Socket on the Charge Controller

Pin Assignment of the PC's Serial Interface

Setting

Value

Bits per second

300

Data bits

8

Parity

none

Stop bits

1

Flow control

none

Pin

Function

Level

Description

1

Short circuit with PIN 2 must be established

for activating RS232

2

Short circuit with PIN 1 must be established

for activating RS232

3

TXD

RS232, +9 V, − 9 V

charge controller output

4

GND

0 V

reference potential

9

Shield, protective earth

Pin

Function

Level

Description

5

GND

0 V

reference potential

2

RXD

RS232, +9 V, − 9 V

PC input