6.6.3 SMA Operation

The communication between the charge controller and the Sunny Island 5048/2012/2224 allows
the charge controller to be controlled in a coordinated manner. This ensures precise calculation of the
state of charge in the Sunny Island without an additional battery current measuring shunt.
All important operating data of the charge controller can be read on the Sunny Island display. In
addition, the most important values are saved on the Sunny Island SD card.
Up to four charge controllers can be connected in parallel to one Sunny Island system.

More information on installing and connecting the SIC-PB communication interface can be found in
the SIC-PB installation guide.

Pin Assignment of the Micro Ribbon Cable

Pin

Function

Level

Description

8

GND

0 V

reference potential

10

GND

0 V

reference potential

11

RXD

TTL

charge controller input

12

TXD

TTL

charge controller output

SIC50-MPT 1

SIC50-MPT 2

SIC50-MPT 3

SIC50-MPT 4

Sunny Island