Displays and Messages

SB3800U-12:SE2006

SMA America

7-17

Measuring Channels

The communication options support a number of measuring channels and messages
from the Sunny Boy inverters.

The following abbreviations are used:

BFR

Betriebsführungsrechner (Sequential Control System)

SRR

Stromregelungsrechner (Current Control System)

The BFR and SRR are redundant processor control systems for the utility protection
functions.

Measuring Channels

Vpv

:

PV input voltage

Vpv

Setpoint:

MPPT DC voltage target

Iac

:

Grid current

Vac

:

Grid voltage

Fac

:

Grid frequency

Pac

:

Power fed to grid

Vpv-PE:

PV-voltage to earth (For troubleshooting PV ground faults)

Ipv

:

PV current

E-Total

:

Total energy yield

h-Total

:

Total operation hours

h-on:

h-on indicates how long sufficient DC voltage has been applied to
the Sunny Boy and the Sunny Boy has been active including the time
it was not able to feed to the utility with respect to low DC voltage
or operation in stop mode.

Power On

:

Total system start-up counter

Serial Number

:

Serial number of the Sunny Boy

Mode

:

Current operating mode

Grid Type:

Type of grid the Sunny Boy is connected to

Error

:

Description of fault