Displays and Messages

SB3800U-12:SE2006

SMA America

7-9

High DC Input Voltage

The yellow LED is on for 5 seconds, remains off for 3 seconds and then blinks 4 times.
The code is repeated 3 times. If the condition remains the code will continue to be sent.

The inverter has detected a DC input voltage that is too high for safe operation.

WARNING: Disconnect the PV array from the SB3800U
immediately. High DC input voltage can permanently
damage the inverter. Have the input source checked by a
qualified technician.

WARNING: Always test the DC voltage at the DC
disconnect switch before energizing the SB3800U.

5 s

3 s

1 s

1 s

1 s 1 s

LED an

LED aus

The yellow LED is blinking
4 times in short intervals

The signal is repeated 3 times and
then starts from the beginning