SMA SB 3800-U User Manual
Page 61

Displays and Messages
SB3800U-12:SE2006
SMA America
7-13
Fault Messages
In case of a fault condition the LCD switches to “Fault“ mode and the backlight is
activated.
The upper display line indicates one of the three following failure types:
• Disturbance
For example, this Disturbance message would be dis-
played if the SB3800U detected a problem with the fre-
quency of the utility grid. The message would clear
automatically once the condition was corrected. Distur-
bances are typically caused by a measured value ex-
ceeding a predetermined limit, the frequency of the AC
grid for example. The display will show the value of the
error (at:) as well as the present value for the particular
parameter (present:).
• Warning
For example, this Warning message would be displayed
if the inverter detected a problem with the array voltage.
Typically, Warning messages indicate a system condi-
tion that should be investigated. Warning conditions will
not preclude inverter operation.
• Error
For example, this Error message would be displayed if
the inverter detected a problem with the internal ROM.
An Error condition will preclude the inverter from restart-
ing until the condition is cleared.
Note:
Each fault message is displayed for 5 seconds. After
5 seconds, the LCD will once again scroll through its normal
operating screens. The fault condition will be included in the
series of screens until the condition is cleared.
Disturbance Message
Disturbance
Fac-Bfr
Disturbance Details
at:
59.30Hz
present: 59.31Hz
Warning Message
WARNING
VpvMax
Error Message
Error
ROM