beautypg.com

SMA STP 15000TL User Manual

Page 52

background image

Ground-fault monitoring for STP 17000TL-10

Insulation monitoring: R

iso

 > 323.4 kΩ

All-pole sensitive residual-current monitoring unit

Available

Electronic string-current monitoring

Available

String-failure detection

Available

General Data

Width x height x depth, with Electronic Solar
Switch

665 mm x 690 mm x 265 mm

Weight

59 kg

Length x width x height of the packaging

780 mm x 380 mm x 790 mm

Transport weight

65 kg

Climatic category in accordance with
IEC 60721-3-3

4K4H

Environmental category

Outdoors

Pollution degree outside the inverter

3

Pollution degree inside the inverter

2

Operating temperature range

-25°C to +60°C

Maximum permissible value for relative humid-
ity, non-condensing

100%

Maximum operating altitude above mean sea
level (MSL)

3,000 m

Typical noise emission

51 dB(A)

Power loss in night mode

<1 W

Maximum data volume per inverter with Speed-
wire/Webconnect

550 MB/month

Additional data volume when using the Sun-
ny Portal live interface

600 kB/hour

Topology

transformerless

Cooling method

SMA OptiCool

Degree of protection in accordance with
IEC 60529

IP65

Protection class in accordance with IEC 61140

I

11 Technical Data

SMA Solar Technology AG

Operating Manual

STP15-17TL-10-BE-en-10

52