10. Flip the lower enclosure lid up and remove it.
11. Fasten the inverter to the rear panel. Tighten the
two cylindrical screws M5x10 in the threads on
the left-hand and right-hand side of the rear
panel (torque: 6 Nm ± 0.3 Nm) using an Allen
key (AF 4).
12. Ensure that the inverter is securely in place.
13. If the inverter is to be protected against theft, attach the eye bolt and install the padlock:
• Screw the M8 eye bolt into the wall
through the rear panel. When tightened,
the eye of the bolt must be vertical to the
enclosure.
• Lead the shackle of the padlock through the
hole of the eye bolt.
• Close the padlock.
• Keep the key of the padlock in a safe place.
5 Mounting
SMA Solar Technology AG
Operating Manual
STP15-17TL-10-BE-en-10
22