Measure Unbalance cycle

To ensure maximum safety and minimum strain on the machine

and workpiece during turning, you should check the unbalance of

the clamped workpiece and compensate it with a balancing weight.

The TNC provides the Measure Unbalance cycle for this purpose.

The Measure Unbalance cycle determines the unbalance of the

workpiece and calculates the mass and position of a balancing

weight.
To determine unbalance:

Shift the soft-key row in the Manual Operation

mode

Select the

MANUAL CYCLES soft key

Select the

TURNING soft key

Select the MEASURE UNBALANCE soft key
Enter the speed for unbalance detection
Press the NC start button: The cycle starts rotating

the table at a low speed and gradually increases

the speed up to the defined value. The TNC

displays a window that shows the calculated mass

and radial position of the balancing weight.

If you wish to use a different radial position or mass for the

balancing weight, you can overwrite one value and have the other

value recalculated automatically.

Repeat the unbalance measurement after you have

clamped a balancing weight.
In some cases, you may need to place two or more

balancing weights at different positions in order to

compensate unbalance.