8 datum setting with 3-d touch probe, Overview, Datum setting in any axis – HEIDENHAIN TNC 620 (340 56x-03) ISO programming User Manual
Page 363

HEIDENHAIN TNC 620
363
13.8 D
a
tum Set
ting with 3-D T
o
uc
h Pr
obe
13.8 Datum Setting with 3-D Touch
Probe
Overview
The following soft-key functions are available for setting the datum on
an aligned workpiece:
Datum setting in any axis
U
Select the probe function by pressing the PROBING
POS soft key
U
Move the touch probe to a position near the touch
point
U
Use the soft keys to select the probe axis and
direction in which you want to set the datum, such as
Z in direction Z–
U
To probe the workpiece, press the machine START
button
U
Datum
: Enter the nominal coordinate and confirm your
entry with the SET DATUM soft key, see "Writing the
measured values from touch probe cycles in datum
tables", page 354
U
To terminate the probe function, press the END soft
key
Soft key
Function
Page
Datum setting in any axis
Setting a corner as datum
Setting a circle center as datum
Y
X
Z
HEIDENHAIN only gives warranty for the function of the
probing cycles if HEIDENHAIN touch probes are used.
If you use probing functions in a tilted working plane, you
must set 3-D ROT to Active for the Manual Operation and
Automatic operating modes.