Programming: Q Parameters

8.8 A

d

ditional F

unctions

In the part program, program FN 16: F-PRINT to activate the
output:

The TNC then outputs the file PROT1.A through the serial interface:

MEASURING LOG OF IMPELLER CENTER OF GRAVITY

DATE: 27:11:2001

TIME: 8:56:34

NO. OF MEASURED VALUES : = 1

X1 = 149.360

Y1 = 25.509

Z1 = 37.000

STR_MONTH

Month as a string abbreviation from the real-
time clock

YEAR2

Two-digit year from the real-time clock

YEAR4

Four-digit year from the real-time clock

96 FN 16: F-PRINT TNC:\MASKE\MASKE1.A/RS232:\PROT1.A

The FN 16 function overwrites already existing log files
with the same name. Use M_APPEND if you want to append
new log information to an existing log.

If you use FN 16 more than once in the program, the TNC
saves all texts in the file that you defined in the FN 16
function. The file is not output until the TNC reads the END
PGM

block, or you press the NC stop button, or you close

the file with M_CLOSE.

In the FN 16 block, program the format file and the log file
with their respective extensions.

If you enter only the file name for the path of the log file,
the TNC saves the log file in the directory in which the NC
program with the FN 16 function is located.

You can output up to 32 Q parameters per row in the
format description file.

Keyword

Function