New functions of software 340 56x-03, Changed functions of software 340 56x-03 – HEIDENHAIN TNC 620 (340 56x-03) User Manual
Page 12

12
New F
u
nctions of Sof
tw
a
re
340
56x
-03
New Functions of Software
340 56x-03
The M101 function was introduced (see "Automatic tool change if the
tool life expires: M101" on page 152).
Tool tables of the iTNC 530 can now be imported in the TNC 620 and
converted to a valid format (see "Importing tool tables" on page 146).
The CYCL CALL POS function was introduced (see User's Manual for
Cycles).
Local and nonvolatile QL and QR Q parameters were introduced (see
"Principle and Overview" on page 230).
You can now perform a tool usage test before starting the program
(see "Tool usage test" on page 154).
The M138 "Selection of swivel axes" function was introduced (see
"Selecting tilting axes: M138" on page 371).
File functions were introduced (see "File Functions" on page 333).
The "Define coordinate transformations" function was introduced
(see "Defining Coordinate Transformations" on page 334).
The TCPM function was introduced (see "File Functions" on page
333).
Changed Functions of Software
340 56x-03
The status display for Q parameters was improved (see "Checking
and Changing Q Parameters" on page 241).
The LAST_USE column was added to the tool table (see "Tool table:
Standard tool data" on page 140).
The graphic simulation was enhanced and adapted to the iTNC 530
(see "Graphics (Advanced Graphic Features Software Option)" on
page 438).
Touch probe cycles can now also be used in the tilted working plane
(see User's Manual for Cycles).