beautypg.com

Fn 20: wait for: nc and plc synchronization, 8 a d ditional f unctions – HEIDENHAIN iTNC 530 (606 42x-02) User Manual

Page 335

background image

HEIDENHAIN iTNC 530

335

9.8 A

d

ditional F

unctions

FN 20: WAIT FOR: NC and PLC synchronization

With the FN 20: WAIT FOR function you can synchronize the NC and
PLC during a program run. The NC stops machining until the condition
that you have programmed in the FN 20 block is fulfilled. The TNC can
check the following PLC operands:

This function may only be used with the permission of
your machine tool builder.

PLC
operand

Abbreviation

Address range

Marker

M

0 to 4999

Input

I

0 to 31, 128 to 152
64 to 126 (first PL 401 B)
192 to 254 (second PL 401 B)

Output

O

0 to 30
32 to 62 (first PL 401 B)
64 to 94 (second PL 401 B)

Counter

C

48 to 79

Timer

T

0 to 95

Byte

B

0 to 4095

Word

W

0 to 2047

Double
word

D

2048 to 4095

In an FN20 block you can define a condition with a
maximum length of 128 characters.