beautypg.com

8 a d ditional f unctions – HEIDENHAIN iTNC 530 (606 42x-02) User Manual

Page 325

background image

HEIDENHAIN iTNC 530

325

9.8 A

d

ditional F

unctions

In the part program, program FN 16: F-PRINT to activate the
output:

The TNC then outputs the file PROT1.A through the serial interface:

MEASURING LOG OF IMPELLER CENTER OF GRAVITY

DATE: 27:11:2001

TIME: 8:56:34

NO. OF MEASURED VALUES : = 1

X1 = 149.360

Y1 = 25.509

Z1 = 37.000

DAY

Day from the real-time clock

MONTH

Month as a number from the real-time clock

STR_MONTH

Month as a string abbreviation from the real-
time clock

YEAR2

Two-digit year from the real-time clock

YEAR4

Four-digit year from the real-time clock

96 FN 16: F-PRINT TNC:\MASKE\MASKE1.A/RS232:\PROT1.A

The output file is not stored until the TNC reads the END
PGM

block, or you press the NC stop button, or you close

the file with M_CLOSE.

In the FN 16 block, program the format file and the log file
with their respective extensions.

If you enter only the file name for the path of the log file,
the TNC saves the log file in the directory in which the NC
program with the FN 16 function is located.

You can output up to 32 Q parameters per line in the
format description file.

Keyword

Function