8 a d ditional f unctions – HEIDENHAIN iTNC 530 (606 42x-02) User Manual
Page 325

HEIDENHAIN iTNC 530
325
9.8 A
d
ditional F
unctions
In the part program, program FN 16: F-PRINT to activate the
output:
The TNC then outputs the file PROT1.A through the serial interface:
MEASURING LOG OF IMPELLER CENTER OF GRAVITY
DATE: 27:11:2001
TIME: 8:56:34
NO. OF MEASURED VALUES : = 1
X1 = 149.360
Y1 = 25.509
Z1 = 37.000
DAY
Day from the real-time clock
MONTH
Month as a number from the real-time clock
STR_MONTH
Month as a string abbreviation from the real-
time clock
YEAR2
Two-digit year from the real-time clock
YEAR4
Four-digit year from the real-time clock
96 FN 16: F-PRINT TNC:\MASKE\MASKE1.A/RS232:\PROT1.A
The output file is not stored until the TNC reads the END
PGM
block, or you press the NC stop button, or you close
the file with M_CLOSE.
In the FN 16 block, program the format file and the log file
with their respective extensions.
If you enter only the file name for the path of the log file,
the TNC saves the log file in the directory in which the NC
program with the FN 16 function is located.
You can output up to 32 Q parameters per line in the
format description file.
Keyword
Function