Output format of the parameter list – HEIDENHAIN ND 221 B v.2 User Manual
Page 34

34
Output Format of the Parameter List
1st line
Each parameter output begins with the start character < * > ( HEX: 0x2A)
*
3 characters
2nd line
Output of the counter designation
N D - 2 2 1 B M M
13 characters 5 characters 2 characters
Model of display unit unit of meas. end of line
Subsequent lines for the individual parameters:
a: Parameters:
Parameter settings can be changed with the MINUS key (e.g.: counting direction positive/counting direction negative etc.)
Examples:
P 1 1 S C L = S C A L I N G . O F F = 0
15 characters 3 char. 13 characters 3 char. 6 characters 2 characters
P 5 0 R S 2 3 2 . = 3 8 4 0 0 B A U D = 3 8 4 0 0
15 characters 3 char. 13 characters 3 char. 6 characters 2 characters
Parameter designation Text Separator Parameter in plain language Separator Parameter value End of line
left-aligned right-aligned block right-aligned block right-aligned
Output Format of the Parameter List