List of operating parameters – HEIDENHAIN ND 221 B v.2 User Manual
Page 16

16
Parameter
Settings / Function
P00 CODE
Enter a code number:
9 51 48:
To change the protected
operating parameters
10 52 96: Nonlinear axis error compensation
24 65 84: To lock the keyboard
66 55 44: To show the software version
24 65 82: Distance-to-go display
48 61 53: Input and output of parameter
and compensation value lists
P01
Units of measurement
Display in millimeters
MM
Display in inches
INCH
P11 SCL
Scaling factor
Scaling factor off
SCALING OFF
Scaling factor on
SCALING ON
P12 SCL
Scaling factor
Enter a numerical value
0.100000 < P12 < 9.999999
Default setting: 1.000000
P30 DIR
Counting direction
Positive counting direction with
positive direction of traverse DIRECT. POS
Negative counting direction with
positive direction of traverse DIRECT. NEG
List of Operating Parameters
List of Operating Parameters
Parameter
Settings/ Function
P31 S. PER.
Signal period of encoder
0.000 000 01 < P31 < 99 999.9999 µm
Default setting: 10 µm
P33 COUNT
Counting mode
0-1-2-3-4-5-6-7-8-9
COUNT 0-1
0-2-4-6-8
COUNT 0-2
0-5
COUNT 0-5
P38 DP POS
Decimal places
1)
1 / 2 / 3 / 4 / 5 / 6
(up to 8 for inch display)
P40 COMP.
Select encoder compensation
No compensation
COMP. OFF
Nonlinear: up to 64 compensation points for
linear encoders
NONL. COMP
Linear compensation
COMP. ON
1)
Depends on signal period (P31) and measuring unit (P01)