beautypg.com

HEIDENHAIN ND 221 B v.2 User Manual

Page 32

background image

32

Input/Output of Parameter and Compensation-Value
Lists

Calling the "data transfer" function:

Select the operating parameters.

together

with

Select P00 CODE.

P00 CODE

MOD

Enter code number 48 61 53 and confirm
with ENT.

Data transfer function:

TRANSFER

SEND PARAM.

or

Continue with ENT.

Press the ENT key if you want to transmit
the parameter list over the RS-232-C/V.24
interface. After transmission, return to the
beginning to transmit or receive further
lists. Press the decimal point key to
continue in the data transmission menu.

REC. PARAM.

The display unit is ready to receive a
parameter list over the RS-232-C/V.24
interface. After successful reception of the
parameter list, the display unit resets itself
and restarts. Continue in the data transfer
menu with the decimal point key.

if
reqd.

or

SEND COMP.

With the ENT key, you transmit the
compensation value list over the RS-232-C/
V.24 interface. After transmission, return to
the beginning to transmit or receive more
lists. Continue in the data transfer menu with
the decimal point key.

REC. COMP.

The display unit is ready to receive a
parameter list over the RS-232-C/V.24
interface. After successful reception, return
to the beginning to transmit or receive more
lists. Continue in the data transfer menu with
the decimal point key.

if
reqd.

or

Exit the data transfer function.

Input/Output of Parameter and Compensation-Value Lists

if
reqd.

if
reqd.

or