HEIDENHAIN ND 221 B v.2 User Manual
Page 32

32
Input/Output of Parameter and Compensation-Value
Lists
Calling the "data transfer" function:
Select the operating parameters.
together
with
Select P00 CODE.
P00 CODE
MOD
Enter code number 48 61 53 and confirm
with ENT.
Data transfer function:
TRANSFER
SEND PARAM.
or
Continue with ENT.
Press the ENT key if you want to transmit
the parameter list over the RS-232-C/V.24
interface. After transmission, return to the
beginning to transmit or receive further
lists. Press the decimal point key to
continue in the data transmission menu.
REC. PARAM.
The display unit is ready to receive a
parameter list over the RS-232-C/V.24
interface. After successful reception of the
parameter list, the display unit resets itself
and restarts. Continue in the data transfer
menu with the decimal point key.
if
reqd.
or
SEND COMP.
With the ENT key, you transmit the
compensation value list over the RS-232-C/
V.24 interface. After transmission, return to
the beginning to transmit or receive more
lists. Continue in the data transfer menu with
the decimal point key.
REC. COMP.
The display unit is ready to receive a
parameter list over the RS-232-C/V.24
interface. After successful reception, return
to the beginning to transmit or receive more
lists. Continue in the data transfer menu with
the decimal point key.
if
reqd.
or
Exit the data transfer function.
Input/Output of Parameter and Compensation-Value Lists
if
reqd.
if
reqd.
or