MAINTENANCE

Gearcases

Transfer Case

Always check and change the fluid at the intervals outlined in the Peri-

odic Maintenance Chart beginning on page 75. Refer to the Gearcase

Specifications Chart on page 92 for recommended lubricants, capacities

and torque specifications.

Fluid Check
The fill plug and level check plug are located on the left side of the

transfer case. The fluid level is sufficient when fluid flows out of the

check plug hole at step 4.
1. Position the vehicle on a level surface.
2. Remove the fill plug.
3. Remove the level check plug.
4. Add the recommended fluid to the fill plug hole until it begins to

flow out of the check plug hole.

5. Reinstall the level check plug. Torque to specification.
6. Reinstall the fill plug. Torque to specification.

Fill Plug

Level

Check

Plug

Drain Plug