Battery Installation

WARNING! Improperly connecting or disconnecting battery

cables can result in an explosion and cause serious injury or death.

When removing the battery, always disconnect the negative (black)

cable first. When reinstalling the battery, always connect the negative

(black) cable last.
NOTICE: Do not remove the battery cables while the engine is

running. Doing so may damage the Electronic Control Unit

(ECM). Take great care not to reverse the battery leads

when installing the battery. Reverse power applied to the

ECM will damage it instantly.

1. Inspect the battery box for damage. Be sure pads are in

good condition and properly located.

2. Make sure cable ends and battery terminals are clean.

Apply a light film of dielectric grease to the terminal

bolt threads.

3. Carefully position the battery into the battery box with

the negative (-) terminal toward the front of the

motorcycle.

4. Make sure the positive (+) cable is routed horizontally

and perpendicular to the long side of the battery.

Connect the positive (+) cable to the positive (+) battery

terminal.

Torque: 45 in-lbs (5 Nm)

5. Install the negative (-) ground cable last.

Torque: 45 in-lbs (5 Nm)

6. Reinstall the battery hold-down strap.

Torque: 96 in-lbs (10.8 Nm)

7. Reinstall the seat. See page 82.

Battery Charging

If your motorcycle will not be used for a period of four (4)

weeks or longer, a maintenance charger should be

connected to the battery. A maintenance charger can be

purchased through your authorized INDIAN MOTORCYCLE

dealer.
1. Following the charger manufacturer’s instructions, use a

battery charger designed for use with 12-volt batteries.

The charger should have a maximum charging rate of

1.8 amps. Charge the battery for approximately 10

hours at a rate of 1.8 amps. If you use a taper or trickle

charger, it will take longer to charge the battery.

2. After charging the battery, allow the battery to sit 1-2

hours before checking the state of charge with a DC volt

meter. The charge should be a minimum of 12.5 DC

volts. Repeat the charging cycle if the charge is less than

12.5 DC volts. Replace the battery if it fails to reach 12.5