Cable macintosh systems – Grass Valley K2 FCP Connect v.2.0.0 User Manual

Page 23

background image

5. On the Xtend SAN uninstall screen, make sure you click

Done

. If you do not do

so, the K2 FCP Connect uninstallation stalls.

NOTE: The Xtend SAN screen can be partially obscured behind the K2 FCP
Connect install screen.

6. Click

Close

when the uninstallation completes successfully.

All files associated with K2 FCP Connect are removed from the Macintosh system.

If an application that is currently installed on the Macintosh system requires Mono
software, you must re-install the Mono software.

Cable Macintosh systems

Connect each Macintosh system as follows. If you have multiple Macintosh systems
and a redundant K2 SAN, balance Macintosh systems between A and B switches.
Refer to the K2 SAN Installation and Service Manual for more information about SAN
connections.

1. Connect GigE port 1 to a control port on the Ethernet switch.

2. Do one of the following:

If CIFS access, no further connections are required.

If iSCSI access, connect GigE port 2 to a media port on the K2 SAN Ethernet
switch. This connection is for the media (iSCSI) network.

22 October 2010

K2 FCP Connect Installation Manual

23

Installing and configuring K2 FCP Connect