Media Converters — Instruction Manual

Installation and Operation

6.

Install up to 18 modules in either frame type of any mix of TX/RX and
VMC/MVMC modules. Six VMC modules are shown installed in

Figure 21

.

VMC and MVMC Module Cabling in VMCR Frames

Once modules have been installed in either frame type, cable the RX and
TX BNC connections for either VMCs or MVMCs as detailed below.

Note

If you have installed the VMCR-18-R in a rack, pull the frame out to its
maximum length before cabling to allow sufficient cable length for pulling the
frame in and out.

Electrical (BNC) Connections

1.

For TX (electrical to fiber) modules, connect the electrical signals to be
converted to fiber to the corresponding TX BNCs on the frame.

2.

For RX (fiber to electrical) modules, connect coaxial cable for the
electrical outputs to the corresponding RX BNCs.

Figure 21. Modules Installed

Connect coaxial cable
to RX output BNCs.

Connect electrical signals
to input TX BNCs.