8985PRC — Instruction Manual

29

Configuration

Status Web Page

Use
this
link

The Status web page (

Figure 10 on page 31

) reports information and status

about the front media and rear modules and any submodules present (if
applicable for the module) in both graphical (using color to indicate status)
and textual formats. It also reports the status of the input and reference
video signals to the module and submodules, and the Frame Bus status.
Video and reference signal reporting can be enabled and disabled at the
module level on the I/O Config web page (

page 32

).

In general, graphics and text colors used for status indication are the fol-
lowing:

Green = Pass – signal or reference present, no problems detected.

Red = Fault – fault condition.

Yellow = Warning – signal is absent, has errors, or is mis-configured.

Gray = Not monitored.

Note

Always refresh the page first with the Refresh button at the top of the page
(shown at left) to update the current status of the web page.

Web Page Header

The content of the web page header for the module is described in detail in

Web Page Header on page 29

.

Module Physical Structure

Status is reported for the front, rear, and optional submodules as follows:

Rear Module – the presence, name, and internal status of the rear
module is reported in the graphic on the left. If the rear module is the
wrong type or missing, the graphic will indicate the status by color and
text within the graphic.

Front Processing Module – the presence, name, and internal status of
the front processing module is reported in the graphic on the right. The
graphic will indicate the status of the front module by color and text
within the graphic.

Fiber Module – the optional fiber optic submodule status will be shown
in the box on the front module graphic. When a fiber optic submodule
is installed, the type will be reported in the top header and the Status
text below the graphic on the right.

Genlock Submodule – the 8900GEN-SM submodule is not used on this
module.