Grass Valley 8950ADC User Manual
Page 16

16
8950ADC Instruction Manual
Configuration
provides a complete summary of the 8950ADC processing func-
tions and a comparison of the functionality available with each control type
along with the ranges and default values for each parameter.
Table 4. Summary of 8950ADC Configuration Functions
Function
Type
Default
Range/Choices
Resolution
Web Page/
Function Name
Rotary Switch
Bank/Setting
Newton
Control
Panel
Notes/
Conditions
Format/Standard
GBR
SMPTE
Levels/
Format/Standard pulldown
1:6
RCSD
Selecting format
recalls factory
defaults for that
standard.
GBR
1:7
Beta (US/525)
1:3
Beta (Japan/525)
1:4
MII (US/525)
1:1
MII (Japan/525)
1:2
EBU N10 (625)
1:5
Levels control action
Independent
Independent or
Locked
Levels/
Control Action pulldown
1:8
CNAC
Adjust each
video level sepa-
rately or tie con-
trols together.
All formats.
Y/G video level
100%
50 to 126.4%
1
(0.8% steps)
Levels/
Y/G Video (%) control
1:A
YGCI
Cb/B video level
100%
48 to 126.4%
1
(0.8% steps)
Levels/
Cb/B Video (%) control
1:B
CBCI
Cr/R video level
100%
51.2 to 126.4%
1
(0.8% steps)
Levels/
Cb/B Video (%) control
1:C
CRCI
Adjust all black
levels together
–
–
Levels/
Control Action set to Locked
1:9
–
Use any black
control
Y/G Black level
100%
84.3 to 158%
1
(0.29% steps)
Levels/
Y/G Black (%) control
1:D
YGBI
All formats
Cr/R Black level
100%
41.4 to 104.9%
(0.29% steps)
Levels/
Cr/R Black (%) control
1:E
CBBI
SMPTE,
MII (US/525),
MII (Japan/625)
EBU N10 (625)
Cb/B Black level
100%
40.8 to 103.7%
(0.29% steps)
Levels/
Cb/B Black (%) control
1:F
CRBI
Cr/R Black Beta level
100%
41.4 to 105%
(0.29% steps)
Levels/
Cr/R Black Beta (%) control
1:E
CBLB
Beta (US/525)
Beta (Japan/525)
Cb/B Black Beta level
100%
40.8 to 103.7%
(0.29% steps)
Levels/
Cb/B Black Beta (%) control
1:F
RBLB
Cr/R Black GBR level
100%
84.3 to 158.2%
(0.29% steps)
Levels/
Cr/R Black GBR (%) control
1:E
BBLG
GBR format
Cb/B Black GBR level
100%
84.3 to 158.2%
(0.29% steps)
Levels/
Cb/B Black GBR (%) control
1:F
RBLG
Horizontal delay
adjust
0 ns
0 to 148000 ns
(37 ns steps)
Timing/Blanking/
Horizontal Delay (ns) control
2:4
HDZI
See
Set SAV/EAV position
29
0 to 255
(1 unit steps)
Timing/Blanking/
EAV/SAV Position control
2:5
ESVI
Sync Source
Y/G
Channel
Y/G Channel or
External
Timing/Blanking/
Sync Source pulldown
2:2
SSRC
Vertical Blanking
Short
Short or Wide
Timing/Blanking/
Vertical Blanking pulldown
2:6
VBLK
See