8947RDA-D/-FR — Instruction Manual

57

Service

Table 11

below describes the different type of alarms that can occur on the

8947RDA-FR module and Fiber Optic SFP devices.

Table 11. List of Alarms for 8947RDA-FR Module and Fiber Optic SFP Device

Alarm

Type

Web Page Description

LED

Comments

Query status

towards

Net Card &

SNMP

Warning

Optic device missing

PRES OPT MODE

(green)

No optical module detected (missing or not plugged)

Warning

Signal not Present on BNC Input

PRES COAX IN

(green)

Status web page:
The electrical input arrow is yellow
Settings web page:
The carrier detect option is not present

Yes

Warning

Reclocker not locked

LOCK 1

(green)

Status web page:
Reclocker not locked
Settings web page:
The Locked rate is displayed

Warning

Signal Not Present on Optic Input 1

PRES OPT IN 1

(yellow)

Status web page:
The optic input arrow 1 is yellow

Yes

Warning

Signal Not Present on Optic Input 2

PRES OPT IN 2

(yellow)

Status web page:
The optic input arrow 2 is yellow

No

Warning

Wrong Rear Module

N/A

Status web page:
The rear module is not compatible with the front module

Fiber Optic SFP device Fault Reporting Summary

Fault

Optical 1 or 2 internal temperature exceed high alarm level

Fault

Optical 1 or 2 internal temperature is below low alarm level

Fault

Optical 1 or 2 internal supply voltage is below low alarm level

Fault

Optical 1 or 2 internal TX Bias current exceeds high alarm level

Fault

Optical 1 or 2 internal TX Bias level is below low alarm level

Fault

Optical 1 or 2 internal TX output power level exceeds high alarm level

Fault

Optical 1 or 2 internal TX output power level is below low alarm level

Fault

Optical 1 or 2 internal RX output power exceeds high alarm level

Fault

Optical 1 or 2 internal RX output power is below low alarm level