8947RDA-D/-FR — Instruction Manual

33

Remote Configuration

8947RDA-D Settings Web Page

Use
this
link

The Settings web page for an 8947RDA-D (

Figure 13 on page 34

) provides

controls for configuring and reporting status of DA signals.

The

Routing Mode

area allows selecting the outputs for DA1 and DA2.

Coax In 1

– Selection of J9 BNC coax input feeds outputs J1, J3, J5, J7.

Coax In 2

– Selection of J10 BNC coax input feeds outputs J2, J4, J6, J8.

Note

Coax In 1

or

Coax In 2

can be configured to feed all eight outputs

for using the module as a single DA.

Coax Signal Names

– Signal names can be entered for Coax Input J9 and Coax

Input J10. These names will be recognized for SNMP reporting.

Other Settings and Reporting

Input Reporting

– Choose between

Enable

or

Disable

. The

Enable

parameter

sends alarms to the 8900NET module on the input signals (presence of
signal). The color of arrows on the module Status web page will be auto-
matically changed.

The

Disable

parameter will change the color of arrows on the Status web

page to gray to show they are not being monitored or reported to upper
level control devices.

Equalizer Mode

– Set the equalizer to

Active

or

Bypass

.

Reclock Mode

– Set the reclock mode to

Auto

or to the specific data rate:

Auto (disables

Signal Format

selection)

143Mb/s

177Mb/s

270Mb/s

360Mb/s

540Mb/s

1485Mb/s

ASI

Signal Format

– Select the signal format as

SD/ASI

or

HD

. This setting will be

grayed out as

N/A

when

Auto

Reclock Mode is selected.

Carrier Detect

– Reports if the module detects a valid carrier as

Present

or

Not

Present

.

Locked Rate

– Reports the data rate the module is locked to or if it is not

locked reports

Not Locked

or

N/A

.