Table 1, Configuration switches s1 and s2 – Grass Valley 8947RDA-D User Manual
Page 15

8947RDA-D/-FR — Instruction Manual
15
Installation
Configuration Switches S1 and S2
gives the configuration parameters set with the onboard switches
S1 and S2 on the front of the 8947RDA-D circuit board.
gives the configuration parameters set with the onboard
switches S1 and S2 on the front of the 8947RDA-FR circuit board.
Parameters may also be set using the web page controls or the Newton
Control panel when the 8900NET module is installed in the GeckoFlex
frame.
Note
Remote control settings made with the web interface will override local set-
tings. To lock out remote control, set the Config Mode to Off (LOCAL).
Table 1. 8947RDA-D Switch S1 and S2 Settings
Switches S1 and S2
Function
Pin
0 (Left/Off)
1 (Right/On)
Switch S2
Config Mode
1
LOCAL (Remote control locked out)
LCL&REM (Local and Remote)
Factory Mode
2
Off
Factory use only
Test Mode
3
Off
Factory use only
Tx Opt Mode
4
Not applicable for the 8947RDA-D
Switch S1
Input Select-Signal Routing
Set Coax Input Mode
Coax In J9
1
1
For Dual mode, Coax in J1 and J10, set Switch S1, pins 1 and 2 to either 00 or 11.
Coax In J10
Coax In J9 (single)
Coax In J10 (single)
1
0
1
1
0
2
0
1
0
1
Coax Outputs Mode
J1, J2, J3, J4
J3, J5, J7, J9
J1, J2, J3, J4,
J5, J6, J7, J8
J1, J2, J3, J4,
J5, J6, J7, J8
Eq. Mode
3
Bypass
Active
Rck Rate Sel (Reclocking rate selection)
4
Not applicable for the 8947RDA-D
5
6
7
Output Mode
8
SD
HD