beautypg.com

Table 1, Configuration switches s1 and s2 – Grass Valley 8947RDA-D User Manual

Page 15

background image

8947RDA-D/-FR — Instruction Manual

15

Installation

Configuration Switches S1 and S2

Table 1

gives the configuration parameters set with the onboard switches

S1 and S2 on the front of the 8947RDA-D circuit board.

Table 2 on page 16

gives the configuration parameters set with the onboard

switches S1 and S2 on the front of the 8947RDA-FR circuit board.

Parameters may also be set using the web page controls or the Newton
Control panel when the 8900NET module is installed in the GeckoFlex
frame.

Note

Remote control settings made with the web interface will override local set-
tings. To lock out remote control, set the Config Mode to Off (LOCAL).

Table 1. 8947RDA-D Switch S1 and S2 Settings

Switches S1 and S2

Function

Pin

0 (Left/Off)

1 (Right/On)

Switch S2

Config Mode

1

LOCAL (Remote control locked out)

LCL&REM (Local and Remote)

Factory Mode

2

Off

Factory use only

Test Mode

3

Off

Factory use only

Tx Opt Mode

4

Not applicable for the 8947RDA-D

Switch S1

Input Select-Signal Routing

Set Coax Input Mode

Coax In J9

1

1

For Dual mode, Coax in J1 and J10, set Switch S1, pins 1 and 2 to either 00 or 11.

Coax In J10

Coax In J9 (single)

Coax In J10 (single)

1

0

1

1

0

2

0

1

0

1

Coax Outputs Mode

J1, J2, J3, J4

J3, J5, J7, J9

J1, J2, J3, J4,

J5, J6, J7, J8

J1, J2, J3, J4,

J5, J6, J7, J8

Eq. Mode

3

Bypass

Active

Rck Rate Sel (Reclocking rate selection)

4

Not applicable for the 8947RDA-D

5

6

7

Output Mode

8

SD

HD

This manual is related to the following products: