Alarm summary tables – Grass Valley 8947RDA-D User Manual
Page 56

56
8947RDA-D/-FR — Instruction Manual
Service
Alarm Summary Tables
below describes the different type of alarms that can occur on the
8947RDA-D module.
Table 10. List of Alarms for 8947RDA-D Module
Alarm
Type
Web Page Description
LED
Comments
Query status
towards
Net Card &
SNMP
Warning
Signal not Present on BNC Input 1
PRES COAX IN
(green)
Status web page:
The electrical input arrow is yellow
Settings web page:
The carrier detect option is not present
Yes
Warning
Signal not Present on BNC Input 2
PRES COAX IN
(green)
Status web page:
The electrical input arrow is yellow
Settings web page:
The carrier detect option is not present
Yes
Warning
Reclocker not locked on DA 1
LOCK 1
(green)
Status web page:
Reclocker not locked
Settings web page:
The Locked rate is displayed
Warning
Reclocker not locked on DA 1
LOCK 2
(green)
Status web page:
Reclocker not locked
Settings web page:
The Locked rate is displayed
Warning
Wrong Rear Module
N/A
Status web page:
The rear module is not compatible with the front module