Grass Valley 2040RDA-16FR User Manual
Page 33
2040RDA-FR/16FR — Instruction Manual
33
Configuration and Adjustments
Dual Optical Transmitter Settings (Tx-Tx 1310NM Submodule)
With the Dual Optical Transmitter submodule installed, the Settings web
page (
) will provide the following controls for the module:
•
Mode –
set the reclocking mode to one of the following with the Mode
pulldown:
•
Auto ASI
– set to ASI default mode for most multiple applications for
auto detection of the relocking rate. If the signal cannot lock, it will
bypass reclocking automatically. DVB-ASI signals are supported in
this mode, while 177M signals are not.
•
Auto 177M
– set to 177M default mode for applications where specific
rate requirements are needed to differentiate from ASI. If the signal
cannot lock, it will bypass reclocking automatically. 177M signals
are supported in this mode, while DVB-ASI signals are not.
•
Bypass
– reclocking is completely bypassed.
•
Reclk 143M
,
Reclk 177M
,
Reclk 270M
,
Reclk 360M
,
Reclk 540M
,
or
Reclk 1485M
– set the module to lock to a specific reclock rate. If the
signal cannot lock to the selected rate, the output will be invalid.
•
Optic 1 TX
– enable or disable the Optic 1 output with the pulldown.
•
Optic 2 TX
– enable or disable the Optic 2 output with the pulldown.
Figure 23. Dual Transmitter Settings Web Page