2040RDA-FR/16FR — Instruction Manual

11

Installation

Figure 1. Module Configuration Jumpers

8269_06r1

Jumper across pins 1–2
to lock out remote control.

Jumper across pins 2–3
to enable remote and
local control.

LOC

LOC&

REM

Jumper across pins 1–2
selects automatic reclocking.

Jumper across pins 2–3
bypasses reclocking function.

Remote Control Lockout

Auto/Bypass Reclocking

JP1

AUTO

BPSS

JP4

Set JP2 and JP3 for input
according to module
silkscreen.

1

0

Input Select

JP2

1

0

JP3