Input/Output Select Jumpers

Set jumpers JP2 and JP3 to 0 (pins 2-3) or 1 (pins 1-2) to select the
input/output type and/or optic output enable according to the silkscreen
on the front module shown in

Figure 2

.

Note

The silkscreen on the module reflects an older version set of SFP submod-
ules. The older version submodules may still be used, but newer submod-
ules, SFP-13103G-M1TRX (DTL Dual Transmitter) and SFP-13103G-M1TRX
(TRL Transceiver) will only work with the newer version software.

These jumper settings can be overridden by remote control. When this con-
dition occurs, the front edge yellow REM OVR LED will light (refer to

Table 1 on page 23

).

Note

The Dual Receiver function is not used at this time.

Figure 2. 2040RDA-FR and 2040RDA-16FR Front Module Silkscreen

Auto/Bypass Jumper

In Local mode, the module will operate in

Auto

or

Bypass

mode.

When set to

Auto

mode, the module will automatically reclock the incoming

signal to 143 Mb/s, 270 Mb/s, 360 Mb/s, 540 Mb/s, or 1.485 Gb/s rates
(ASI 270 signals). If the input signal cannot lock to one of these rates, the
reclocking will be bypassed automatically.

When set to

Bypass

mode, the reclocking will be bypassed completely.

Set jumper JP4 for auto-reclocking (AUTO pins 1-2) or to bypass reclocking
(BPSS pins 2-3). This jumper setting can be overridden by remote control.
When the module is in Bypass, the front edge LD LED will be off (refer to

Table 1 on page 23

).