2040RDA-FR/16FR — Instruction Manual
Installation
Input/Output Select Jumpers
Set jumpers JP2 and JP3 to 0 (pins 2-3) or 1 (pins 1-2) to select the
input/output type and/or optic output enable according to the silkscreen
on the front module shown in
.
Note
The silkscreen on the module reflects an older version set of SFP submod-
ules. The older version submodules may still be used, but newer submod-
ules, SFP-13103G-M1TRX (DTL Dual Transmitter) and SFP-13103G-M1TRX
(TRL Transceiver) will only work with the newer version software.
These jumper settings can be overridden by remote control. When this con-
dition occurs, the front edge yellow REM OVR LED will light (refer to
).
Note
The Dual Receiver function is not used at this time.
Figure 2. 2040RDA-FR and 2040RDA-16FR Front Module Silkscreen
Auto/Bypass Jumper
In Local mode, the module will operate in
Auto
or
Bypass
mode.
When set to
Auto
mode, the module will automatically reclock the incoming
signal to 143 Mb/s, 270 Mb/s, 360 Mb/s, 540 Mb/s, or 1.485 Gb/s rates
(ASI 270 signals). If the input signal cannot lock to one of these rates, the
reclocking will be bypassed automatically.
When set to
Bypass
mode, the reclocking will be bypassed completely.
Set jumper JP4 for auto-reclocking (AUTO pins 1-2) or to bypass reclocking
(BPSS pins 2-3). This jumper setting can be overridden by remote control.
When the module is in Bypass, the front edge LD LED will be off (refer to
).