Cabling, 2040rda-fr or 2040rda-16fr with no sfp option – Grass Valley 2040RDA-16FR User Manual

Page 18

background image

18

2040RDA-FR/16FR — Instruction Manual

Installation

Cabling

All cabling to the 2040RDA-FR or 2040RDA-16FR module sets is done on
the corresponding Single Height 2040RDA-FR or Dual Height
2040RDA-16FR rear module at the back of the 2000 frame.

Cabling of the rear module depends on what SFP option is installed as fol-
lows:

2040RDA-FR or 2040RDA-16FR with no SFP Optical submodule option
(electrical only) (

page 18

)

2040RDA-FR or 2040RDA-16FR with SFP-13103G-M1DTX (Dual
Optical Transmitter) option (

page 20

)

2040RDA-FR or 2040RDA-16FR with SFP-13103G-M1TRX (Optical
Transceiver) option (

page 21

)

2040RDA-FR or 2040RDA-16FR with No SFP Option

The 2040RDA-FR or 2040RDA-16FR can input one electrical SD/HD/ASI
input with either eight or sixteen electrical outputs. On-board jumpers JP2
and JP3 on the circuit board have no effect and can be set for any configu-
ration. Refer to

Figure 12

for an illustration of the input and output BNCs

for 2040RDA-FR or refer to

Figure 13

for an illustration of the input and

output BNCs for 2040RDA-16FR.

Figure 12. 2040RDA-FR Rear Module Input/Output Connectors

Figure 13. 2040RDA-16FR Rear Module Input/Output Connectors

J6

J7

J8

J9

J10

2040RDA

-FR

J5

J3

J4

J2

J1

Input

SFP Submodule
connector cage

8360_01

Outputs BNC J1, J3-J9

J6

J7

J8

J9

2040

RDA-16

J5

J3

J4

J2

J1

J15

J16

J17

Input

J14

J12

J13

J11

J10

SFP Submodule
connector cage

8269_02

Outputs J1 – J8

Outputs J9 – J16