2040RDA-FR/16FR — Instruction Manual
Configuration and Adjustments
Settings Web Page Status Reporting
The following read-only status items are also reported on the Settings web
page:
•
Warning: Front Rear Mismatch
– when a 2040RDA-16FR module is installed
with a 2040RDA-FR-R rear module (only 8 outputs) this warning will
appear on the Settings page. The Status page will report the Internal
State condition as yellow (
) and the front
edge FAULT LED will flash (
Note
This will not occur when a 2040RDA-FR is installed with a 2040RDA-16FR-R
rear module, but only 8 of the 16 BNC outputs will be active.
•
Opt Dev:
– the type of optic device installed will be reported as
No Dev
,
Error
,
Unknown Device
,
Tx-Tx 1310nm
(Dual Transmitter),
Tx-Rx 1310nm
(Input/Output Transceiver),
•
Opt Dev Status:
– the status of the optic device will be reported as
Pass
,
Fault
, or
N/A
.
•
Coax In:
– reports the presence of a valid signal on the Coax input as
Present
,
Not Present
, or
N/A
(not enabled).
•
Optic 1 In:
– reports the presence of a valid signal on the Optic 1 input as
Present
,
Not Present
, or
N/A
(not available or enabled).
•
Optic 2 In:
– reports the presence of a valid signal on the Optic 2 input as
Present
,
Not Present
, or
N/A
(not available or enabled).
•
Reclocker:
– reports whether the signal is
Locked
,
Unlocked
or
N/A
.
•
Auto Rate:
– reports the bit rate currently detected (
143M
,
177M
,
270M
,
360M
,
540M
,
or
1485M
),
N/A
, or
Unknown
.