OAP card configuration commands
oap connect
Syntax
SR6600/SR8800, or S7500E/S9500E/S12500 in standalone mode:
oap connect slot slot-number
S5800:
oap connect slot slot-number system system-name
S7500E/S9500E/S12500 in IRF mode:
oap connect chassis chassis-number slot slot-number
View
User view
Default Level
2: System level
Parameters
slot slot-number: Specifies the OAP card residing in a slot. (SR6600/SR8800, or
S7500E/S9500E/S12500 in standalone mode)
slot slot-number system system-name: Specifies the OAP card residing in a slot on an IRF member device.
(S5800)
chassis chassis-number slot slot-number: Specifies the OAP card residing in a slot on an IRF member
device. (S7500E/S9500E/S12500 in IRF mode)
Description
Use the oap connect command to redirect from the device to the OAP card.
You can press Ctrl+K to return from the operating system of the OAP card to the command line interface
of the device.
Examples
# Redirect from the device to the OAP card in slot 3. (SR6600/SR8800, or S7500E/S9500E/S12500
in standalone mode)
Press CTRL+K to quit.
Connected to OAP!
# Redirect from the device to the OAP card in slot 3 on member device 1 (S5800)
Press CTRL+K to quit.
Connected to SubSlot3
# Redirect from the device to the OAP card in slot 5 on member device 2. (S7500E/S9500E/S12500 in
IRF mode)