beautypg.com

Grounding the firewall with a grounding strip – H3C Technologies H3C SecPath F5000-S Firewall User Manual

Page 23

background image

14

5.

Use a needle-nose pliers to bend a hook at the other end of the grounding cable, attach it to the

grounding point, and secure it with a screw.

Figure 9 Connecting the grounding cable to the grounding point on the rack

Grounding the firewall with a grounding strip

If a grounding strip is available at the installation site, connect the grounding cable through the
grounding strip.
To connect the grounding cable:

1.

Remove the grounding screw from the firewall chassis.

2.

Attach the grounding screw to the ring terminal of the grounding cable.

3.

Use a Phillips screwdriver to fasten the grounding screw into the grounding screw hole.

4.

Remove the hex nut from the grounding strip.

5.

Use a needle-nose pliers to bend a hook at the other end of the grounding cable, attach it to the
grounding point, and secure it with a screw.

This manual is related to the following products: