Item Requirements
Result
Lightning
protection
•
The grounding cable of the chassis is well grounded.
•
The grounding terminal of the AC power receptacle is
well grounded.
•
A power lightning arrester is installed. (Optional)
Electricity safety
•
Equip a UPS.
•
In case of emergency during operation, switch off the
external power switch.
Rack-mounting
requirements
•
Make sure the cabinet is equipped with a good
ventilation system.
•
The rack is sturdy enough to support the weight of the
firewall and installation accessories.
•
The size of the rack is appropriate for the firewall.
•
The front and rear of the rack are at least 0.8 m (31.50 in)
away from walls or other devices.
Safety
precautions
•
The firewall is far away from any moist area and heat source.
•
The emergency power switch in the equipment room is located.
Tools and
accessories
•
Installation accessories supplied with the firewall
•
User supplied tools
Reference
•
Documents shipped with the firewall
•
Online documents